Shenzhen Certainn Technology Co., Ltd.
Member companies
Hangzhou Moptim Medical Equipment Co., Ltd.
Shenzhen certainn technology co., ltd. Zhengzhou branch
Shenzhen certainn technology co., ltd. Wuhan branch
Shenzhen certainn technology co., ltd. Chengdu branch
Shenzhen certainn technology co., ltd. Jinan branch
Shenzhen certainn technology co., ltd. Xian branch

Optical Coherence Tomographer


  • High scanning speed up to 130,000 A-scans/s

    With the capability to perform up to 130,000 A-scans per second, this device ensures fast acquisition of 3D PanoScan images.

  • Comprehensive clarity with 12x12 mm 3D PanoScan

    The Mocean 4000's high definition and widefield 12x12 mm PanoScan feature offers an expansive view in a single scan, revolutionizing the way ophthalmologists assess ocular health. This advanced technology utilizes a unique AI algorithm that significantly enhances image quality, ensuring that no pathological details are overlooked. By delivering a thorough and detailed assessment, the PanoScan feature empowers practitioners with the precision and clarity needed for accurate diagnostics and superior patient care.



  • Real-time SLO with eye tracking

    The Mocean® 4000 system stands out with its unique ability to simultaneously capture cross-sectional OCT imaging and 47-degree fundus imaging via Scanning Laser Ophthalmoscope (SLO). This dual capability provides a detailed overview of the retina, making it easier to pinpoint lesion areas prior to acquisition. The system can capture up to 50 SLO fundus images every second, producing high-definition fundus images. To reduce artifacts caused by eye drift and micro saccades, the Mocean® 4000 is equipped with an SLO-based eye tracker that tracks at 100 times per second with an impressive 10-micron accuracy and over a 95% success rate, ensuring greater reliability and confidence in clinical practice.

  • 16mm full corneal analysis

    The 16mm full cornea scan feature in Mocean 4000 delivers exceptional and comprehensive imaging of the entire corneal structure. This advanced functionality enables ophthalmologists to capture detailed, high-resolution images, facilitating comprehensive analysis and enhanced diagnostic insights.

  • Epithelial thickness mapping

    Provides 6mm diameter cornea epithelium thickness map, which is an important part of diagnostics in refractive surgery, with many important clinical applications.


  • Automatic choroidal thickness analysis


    The Mocean 4000 offers automated choroidal thickness analysis along with progression analysis reports, enabling the study of choroidal thickness changes over time.


  • AI retina anslysis

    The Mocean 4000 utilizes artificial intelligence for retinal image analysis, assisting doctors in making efficient diagnoses.

  • Optional VASCAN™ OCTA Module

    The VASCAN™ OCT Angiography module is an optional software enhancement for the Mocean 4000, offering non-invasive imaging of the eye's vascular structure without dye injections. It features ultraclear angiographic imaging powered by the COMAG algorithm, delivering widefield OCTA imaging up to 12 mm x 8 mm. 

    The SLO-based real-time retinal tracking reduces motion artifacts for precise follow-ups, while an advanced projection artifact removal algorithm ensures accurate visualization of retinal vasculature. 

    The module provides comprehensive quantitative analysis, including density, FAZ, and flow analysis, and supports imaging at various dimensions and slabs, offering detailed views of the retina and optic disc.

Mocean 4000, configured with the high-end SLO-OCT combined imaging systems and SLO-based eye tracker, is a powerful platform for advanced application such as OCT Angiography. 

  • Image gallery
  • Video
  • Specifications
  • Downloads
  • OCT

  • SLO

  • 16 mm angle-to-angle scan

  • HD scan interface

  • Dry AMD

  • Polypoidal choroidal vasculopathy (PCV)

  • Central Serous Chorioretinopathy (CSC)

  • 3D view

  • VASCAN OCTA case BRVO

  • Side view

  • Side view

  • Mocean 4000

  • Mocean 4000

OCT IMAGING

  • Methodology

  • Spectral domain OCT

  • Optical source

  • Super luminescent diode (SLD), 840 nm

  • Scan speed

  • 80,000 A-scans/s or 130,000 A-scans/s (optional)

  • Axial resolution (optical)

  • 5 microns (optical), 2.7 microns (digital)

  • Transverse resolution

  • 15 microns (optical), 3 microns (digital)

  • A-scan depth

  • Anterior segment: 7.36mm, posterior segment: 3.1 mm

  • Diopter range

  • - 20 to + 20 diopters

  • Working distance

  • 30 mm

  • Scan patterns

  • Macular: HD line scan (6 / 12 mm / 16 mm), 3D scan (12 mm x 12 mm), 6-line radial scan, Multi (X-Y: 5 x 5, X:9, Y:9) Disc: 3D scan (6 mm x 6 mm)
    Anterior: HD line scan (6 / 16 mm), 6-line radial scan, full cornea scan (16 mm), lens mode (16 mm)

FUNDUS IMAGING

  • Methodology

  • Line scanning laser ophthalmoscopy (LSLO)

  • Minimum pupil diameter

  • 3.0 mm

  • Field of view

  • 45±1 degrees

VASCAN™ OCTA MODULE (OPTIONAL)

  • Scanning volume/area

  • 3mm x 3mm     256 x 256 A-scans
    6mm x 6mm     512 x 512 A-scans
    8mm x 8mm     512 x 512 A-scans
    12mm x 8mm   756 x 512 A-scans

  • Algorithm

  • COMAG

  • Segmentation options

  • Encoded, Vitreous Retina Interface(VRI), Superficial, Intermediate, Deep, Outer retina, Choriocapillaris, Choroid, Custom

  • Quantitative analysis

  • Density analysis (vessel density, perfusion density), FAZ analysis (FAZ area, perimeter circularity, FD300), impairment analysis, flow area analysis

ELECTRICAL AND PHYSICAL

  • Weight

  • 30.5 kg

  • Dimension

  • 532 mm (L) x 360 mm (W) x 540 mm (H)

  • Source voltage

  • AC 100 - 240 V

  • Frequency

  • 50 Hz - 60 Hz

  • Power input

  • 90 VA